Big Cyber Monday Sale - 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: dm70dm

D-VXR-DY-23 Dell VxRail Deploy 2023 Questions and Answers

Questions 4

In a VxRail Stretched Cluster deployment of 8 nodes on between sites?

Options:

A.

Primary to Witness site RTT: < 250 ms Secondary to Witness site RTT; < 250 ms Primary to Secondary site RTT: < 5 ms

B.

Primary to Witness site RTT: < 150 ms Secondary to Witness site RTT: < 150 ms Primary to Secondary site RTT: < 10 ms

C.

Primary to Witness site RTT: < 200 ms Secondary to Witness site RTT: < 200 ms Primary to Secondary site RTT: <: 5 ms

D.

Primary to Witness site RTT: < 200 ms Secondary to Witness site RTT < 200 ms Primary to Secondary site RTT: < 10 ms

Buy Now
Questions 5

What is a supported witness configuration for a 3+3+1 VxRail Stretched Cluster?

Options:

A.

vSAN Witness appliance with customer provided license

B.

Physical ESXi host with included cluster license

C.

Physical ESXi host with multiple VxRail clusters as witness

D.

vSAN Witness appliance or a physical ESXi host

Buy Now
Questions 6

A VxRail API request has been executed and the user account does not have vCenter privileges to perform the task What code is returned?

Options:

A.

200

B.

207

C.

403

D.

500

Buy Now
Questions 7

A systems engineer needs to check the health of the nodes and the system VMs to prevent complications or failures during VxRail upgrades. Which tool must be used to perform the task?

Options:

A.

VxVerify

B.

CloudlQ

C.

SolVe Online

D.

VxRail ACE

Buy Now
Questions 8

From what environment must a network administrator run VxRail network validation?

Options:

A.

Windows PowerShell command prompt

B.

Same subnet as VxRail Management Network

C.

Top of Rack switches

D.

VxRail Deployment Wizard

Buy Now
Questions 9

What is a valid 2-node VxRail cluster configuration?

Options:

A.

Series with 4x 25 GbE in a direct-connect configuration

B.

Series with 4x 10 GbE in a switch configuration

C.

Series with 4x 1 GbE in a direct-connect configuration

D.

Series with 2x 25 GbE in a switch configuration

Buy Now
Questions 10

Which series of VxRail nodes supports either Intel or AMD processors and either hybrid or All-Flash storage?

Options:

A.

G Series

B.

D Series

C.

E Series

D.

V Series

Buy Now
Questions 11

An implementation engineer logs in to the vSphere Client of a recently deployed VxRail cluster. They want to review the firmware versions on the VxRail nodes.

Which view should they use to gather this information?

Options:

A.

Hosts and Clusters > VxRail Host > Configure > VxRail > iDRAC Configuration

B.

Host and Clusters > VxRail Host > Monitor > VxRail > Physical View

C.

Hosts and Clusters > VxRail Cluster > Monitor > VxRail > Appliances

D.

Hosts and Clusters > VxRail Cluster > Configure > VxRail > System

Buy Now
Questions 12

What is the minimum number of VxRail nodes required for a vSAN storage policy with RAID-5 (Erasure Coding)?

Options:

A.

3

B.

4

C.

5

D.

6

Buy Now
Questions 13

What is the maximum number of supported nodes in a VxRail Stretch Cluster?

Options:

A.

16

B.

30

C.

32

D.

64

Buy Now
Questions 14

What is a consideration when adding nodes to a VxRail G Series chassis?

Options:

A.

G560 and G410 nodes are permitted in the same chassis

B.

In a full G Series chassis, all nodes must have 10GbE ports

C.

Hybrid and All-Flash nodes are permitted, if in different chassis

D.

All nodes in a G Series chassis must be identical

Buy Now
Questions 15

What are the requirements for a customer-supplied VDS in a VxRail deployment?

Options:

A.

4 or 8 uplinks

Port groups for Discovery, Management, vMotion, and vSAN only

B.

2 or 4 uplinks

Port groups for Discovery, Management, vMotion, and vSAN only

C.

2 or 4 uplinks

Port groups for Discovery, Management vCenter Server, vMotion, and vSAN

D.

4 or 8 uplinks

Port groups for Discovery, Management, vCenter Server, vMotion, and vSAN

Buy Now
Questions 16

A VxRail D560 cluster was delivered six months ago and now needs to be prepared for installation with the target code. What is the correct method to complete the task?

Options:

A.

Boot into RASR ISO and perform a RASR Reset

B.

Boot into RASR USB and perform a RASR Reset

C.

Boot into SD card and perform a Factory Reset

D.

Boot into RASR ISO and perform a Factory Reset

Buy Now
Questions 17

A planned VxRail Stretched Cluster will have four hybrid nodes at each site. What is the recommended storage policy to ensure cross-site and local protection, using storage as efficiently as possible?

Options:

A.

Site disaster tolerance – None keep data on Preferred (stretched cluster)

Failures to tolerate – 1 failure – RAID-1 (Mirroring)

B.

Site disaster tolerance – Dual site mirroring (stretched cluster)

Failures to tolerate – 1 failure – RAID-5 (Erasure Coding)

C.

Site disaster tolerance – Dual site mirroring (stretched cluster)

Failures to tolerate – No data redundancy

D.

Site disaster tolerance – Dual site mirroring (stretched cluster)

Failures to tolerate – 1 failure – RAID-1 (Mirroring)

Buy Now
Questions 18

What guideline should be followed when planning bandwidth between sites hosting VM objects and the witness nodes?

Options:

A.

1500 MTU on the VSAN vmkernel interface

B.

5 ms with a recommended minimum bandwidth of 10Gbps

C.

2 Mbps for every 1000 objects on the vSAN

D.

500 ms roundtrip (< 250 ms one way)

Buy Now
Questions 19

Which VxRail model can only be installed with static rack rails?

Options:

A.

D Series

B.

P Series

C.

S Series

D.

G Series

Buy Now
Questions 20

What Is a supported method for racking nodes for a new VxRail deployment?

Options:

A.

In the rack hosting the network equipment used to manage the iDRAC

B.

With PDUs connected to 120v single phase 5-amp electrical circuits

C.

Starting with node 1 at the top of the rack

D.

With server exhaust facing the cold aisle

Buy Now
Questions 21

What is the correct CL! command to collect only the VxRail Manager logs?

Options:

A.

generateFullBundle.py -c

B.

vm-supportsh -c

C.

generateLogBundle py -v

D.

vc-support sh -v

Buy Now
Questions 22

According to the VxRail PEQ Engagement Details worksheet, links to what resources should the SE send to the customer?

Options:

A.

VxRail vCenter Server Planning Guide

Network Validation Tool

B.

VxRail vCenter Server Planning Guide

VxRail Network Planning Guide

C.

VxRail QuickStart Guide

VxRail Network Planning Guide

D.

VxRail QuickStart Guide

Network Validation Tool

Buy Now
Questions 23

A VxRail cluster is being deployed in a DMZ environment. What is the recommended deployment option?

Options:

A.

External vCenter Server with customer-supplied VDS

B.

External vCenter Server with VxRail-deployed VDS

C.

Internal vCenter Server with internal DNS

D.

Internal vCenter Server with external DNS

Buy Now
Questions 24

An implementation engineer is tasked with setting up RecoverPoint for VMs on a single G Series chassis. How many VMs are licensed to be protected on the cluster?

Options:

A.

5

B.

10

C.

15

D.

20

Buy Now
Questions 25

How should an administrator manually validate the DNS readiness of a customer network?

Options:

A.

Run a traceroute to the DNS server

B.

Generate a Network PEQ

C.

Ping the default gateway of the management VLAN

D.

Run nslookup on server FQDN and IP

Buy Now
Questions 26

In addition to hardware monitoring, what is the purpose of the Dell PTAgent service on a VxRail node?

Options:

A.

Hardware discovery and firmware installation

B.

VxRail node discovery and software upgrades

C.

BOSS upgrade and firmware installation

D.

Hardware discovery and VxRail VIB installation

Buy Now
Questions 27

An implementation engineer is expanding an existing VxRail E Series cluster with an additional node The version of the node is not at the current cluster level and is not compatible

What action must be performed before adding the node?

Options:

A.

Order node with correct image

B.

RASR Factory Reset

C.

RASR Factory Image Upgrade

D.

Compute node expansion

Buy Now
Questions 28

An implementation engineer places a VxRail node into maintenance mode using the Ensure accessibility setting What is the engineer likely planning to do?

Options:

A.

Extensive maintenance

B.

Temporary maintenance

C.

Permanent removal of host from cluster

D.

Shutdown of an entire cluster

Buy Now
Questions 29

What is a consideration when performing a VxRail software upgrade from version 4.7.xxx to version 7.0.xxx?

Options:

A.

External vCenter server must be upgraded after the VxRail is upgraded

B.

vCenter Server requires a temporary IP address on a different subnet before the upgrade

C.

Secure boot must be enabled on the ESXi hosts for a successful upgrade

D.

VxRail Manager VM must be changed to the default name to avoid an upgrade failure

Buy Now
Questions 30

What is validated by running the Proactive Network Performance test in vCenter on a VxRail cluster?

Options:

A.

Latency and bandwidth measurement to the witness host

B.

Network configuration and performance for vSAN

C.

Network performance for virtual machines

D.

Latency measurement between DCs for Stretched Clusters

Buy Now
Exam Code: D-VXR-DY-23
Exam Name: Dell VxRail Deploy 2023
Last Update: Dec 7, 2025
Questions: 102

PDF + Testing Engine

$49.5  $164.99

Testing Engine

$37.5  $124.99
buy now D-VXR-DY-23 testing engine

PDF (Q&A)

$31.5  $104.99
buy now D-VXR-DY-23 pdf
dumpsmate guaranteed to pass

24/7 Customer Support

DumpsMate's team of experts is always available to respond your queries on exam preparation. Get professional answers on any topic of the certification syllabus. Our experts will thoroughly satisfy you.

Site Secure

mcafee secure

TESTED 07 Dec 2025