H19-105_V2.0 HCSA-Sales-Data Center Facility V2.0 Questions and Answers

Questions 4

Which technologies does the Huawei FusionModule2000 use to lower PUE in a low-carbon environment?

Select all that apply

Options:

A.

AI-based optimization, saving 8% to 15% cooling

B.

Outdoor direct ventilation, maximizing the use of natural cooling sources

C.

Fluorine pump refrigeration, maximizing natural cooling sources

D.

Fully-adaptive compressor, improving low-load energy efficiency by 15%

Buy Now
Questions 5

Which of the following statements correctly describe the application scenarios of the Huawei smart modular data center solution?

Select all that apply

Options:

A.

FusionModule500 applies to one to two cabinets. The IT load power of a single module is less than 3 kW.

B.

FusionModule2000 applies to 4 to 48 cabinets. The IT load power of a single module is less than 310 kW.

C.

FusionModule5000 applies to 50 to 100 cabinets. The IT load of a single module is less than 1000 kW.

D.

FusionModule800 applies to 1 to 12 cabinets. The IT load of a single module is less than 40 kW.

Buy Now
Questions 6

Which of the following statements about the Huawei high-temperature chilled water fan wall are correct?

Select all that apply

Options:

A.

The DG integrates the PFC module, which reduces the harmonic wave and ensures the safety of the power supply link without the need for APF.

B.

Key components, such as the main control unit, fan drive unit, low-voltage power supply unit, and fan unit, adopt the modular design and support hot swapping and quick maintenance within 1 minute.

C.

Compared with traditional downflow chilled water terminals, no raised floor is required, greatly reducing cooling investment.

D.

Compared with traditional room-level chilled water, the inlet water temperature increases from 15°C to 20°C, reducing the CLF by 15%.

Buy Now
Questions 7

Is it true or false that the standard protection rating of the FusionDC1000A is IP65?

Options:

A.

True

B.

False

Buy Now
Questions 8

In the intelligent computing era, the IT power density of data centers is increasing.

Options:

A.

True

B.

False

Buy Now
Questions 9

Which of the following statements about the Huawei prefabricated modular data center solution are incorrect?

Options:

A.

Property certificates cannot be obtained for prefabricated modular data centers. Therefore, assets must be depreciated by equipment.

B.

The FusionDC1000C uses the in-row air cooling solution.

C.

For a data center with 1000 cabinets, the TTM of the prefabricated modular construction mode is six months, excluding the time for planning and construction application and design.

D.

By default, the power supply module of the FusionDC1000C outside China includes a transformer.

Buy Now
Questions 10

Regarding the integrated UPS used in the FusionModule2000, which of the following statements are correct?

Select all that apply

Options:

A.

The integrated UPS integrates UPS input, output, air conditioner power distribution, and IT power distribution. Compared with the traditional solution, the integrated UPS saves one to two cabinets.

B.

The integrated UPS uses Huawei-developed high-density circuit breakers, reducing the size by 25%. Therefore, more power modules can be housed.

C.

Huawei integrated UPS provides up to 180 kW power per cabinet, the highest power in the industry.

D.

In FusionModule2000 6.0, the integrated UPS can supply power to IT equipment and air conditioners at the same time, ensuring uninterrupted cooling.

Buy Now
Questions 11

For predictive maintenance purposes, which of the following are the main input parameters used by the algorithm that predicts the remaining lifespan of the capacitor in a UPS power module?

Select all that apply

Options:

A.

Temperature

B.

Rotational speed

C.

Ripple

D.

Load Rate

Buy Now
Questions 12

After the water-cooled chilled water cooling system is optimized using the iCooling solution, the PUE (Power Usage Effectiveness) can be reduced by 8% to 15%. Is this statement true or false?

Options:

A.

True

B.

False

Buy Now
Questions 13

Waste batteries used for energy storage can be thrown away together with ordinary household waste.

Options:

A.

True

B.

False

Buy Now
Questions 14

Which of the following is NOT part of the “five understandings” theoretical knowledge that an SQA (Supplier Quality Assurance) engineer is expected to master?

Options:

A.

Quality system

B.

Quality level of competitors in the energy storage industry

C.

Safety standards of electricity and energy storage

D.

Service business

Buy Now
Questions 15

Which of the following does NOT accurately describe the concept behind Huawei's data center facility and critical power solution?

Options:

A.

Smart

B.

Low carbon

C.

Simple

D.

Reliable

Buy Now
Questions 16

Which of the following statements about the grace period management rules for sales partner certification are correct?

Select all that apply

Options:

A.

Grace period for new/upgraded certification:If the capability does not meet the requirements temporarily, the grace period cannot be applied for.

B.

Review the capabilities on the second day after the grace period ends. If the certification threshold is not reached, the certification will be downgraded.

C.

Expiration date of the grace period: not more than 6 months and not more than March 1 of the following year.

D.

Grace period for renewing the certification:The entry requirements for the performance threshold for certification level must be met.

E.

Grace period for new/upgraded certifications:Meet the performance threshold requirements of the corresponding level, or the admission requirements of partners at the same level or higher in the industry.

Buy Now
Questions 17

When an Energy Storage System (ESS) fire alarm activates but only smoke — not flame — is being emitted, which of the following is the correct response action?

Options:

A.

Open the cabinet door, check the point of origin inside, and use a fire extinguisher to put out the fire.

B.

Keep observing the situation remotely. Do not spray water into it for the time being, and pour water onto its surface to cool the temperature. Spray water into it after seeing open flame.

C.

Open the valve for the water sprinkler pipe and start the water pump to inject water into the faulty ESS.

D.

Approach the ESS to measure its temperature with your hand.

Buy Now
Questions 18

Which of the following are components included in the QMS model?

Select all that apply

Options:

A.

Process operations

B.

Leadership

C.

Performance appraisal

D.

Planning

Buy Now
Exam Code: H19-105_V2.0
Exam Name: HCSA-Sales-Data Center Facility V2.0
Last Update: Nov 19, 2026
Questions: 60

PDF + Testing Engine

$42.5  $169.99

Testing Engine

$32.5  $129.99
buy now H19-105_V2.0 testing engine

PDF (Q&A)

$27.5  $109.99
buy now H19-105_V2.0 pdf
dumpsmate guaranteed to pass

24/7 Customer Support

DumpsMate's team of experts is always available to respond your queries on exam preparation. Get professional answers on any topic of the certification syllabus. Our experts will thoroughly satisfy you.

Site Secure

mcafee secure

TESTED 19 Nov 2026