H20-923_V1.0 HCSP-Field-Data Center Facility V1.0 Questions and Answers

Questions 4

In alarm management, the status can be identified by masking rules.

Options:

A.

Invalid

B.

Standard

C.

Maintenance

D.

Valid

Buy Now
Questions 5

The NetEco can be deployed on any virtualization platform.

Options:

A.

True

B.

False

Buy Now
Questions 6

On the ECC800-Pro WebUI, the PUE configuration mode can be "Standard" or "User-defined".

Options:

A.

True

B.

False

Buy Now
Questions 7

The UPS5000-H-1200 kVA and UPS5000-H-1600 kVA have two power cabinets and one bypass cabinet, and are equipped with the MDU, ECU, and surge protection box.

Options:

A.

True

B.

False

Buy Now
Questions 8

In a data center fire protection design, which approach best matches Huawei facility practice for protecting IT rooms while minimizing secondary damage to IT equipment?

Options:

A.

Use only portable extinguishers and rely on manual response

B.

Deploy a smoke detection system plus a clean-agent gas extinguishing system with interlock controls for automatic release

C.

Install a water sprinkler system as the only suppression method inside the IT white space

D.

Disable automatic suppression to avoid accidental discharge

Buy Now
Questions 9

The FusionCol8000-A230 unit uses two systems. Each system uses three compressors connected in parallel and two EEVs.

Options:

A.

True

B.

False

Buy Now
Questions 10

Which of the following is not a scenario-based solution for Huawei data center products?

Options:

A.

FusionDC800

B.

FusionDC1000

C.

FusionModule500

D.

FusionModule2000

Buy Now
Questions 11

Which of the following models is a Huawei in-room chilled water horizontal air supply product?

Options:

A.

NetCol5000-A070U

B.

FusionCol8000-C210H

C.

FusionCol5000-A050H

D.

NetCol8000-C070D

Buy Now
Questions 12

During wizard startup, when you enter the screen for selecting commissioning items for the first time, all items are selected by default. Which item is mandatory. You can deselect other commissioning items that are not mandatory.

Options:

A.

Commissioning the indoor fans

B.

Commissioning the condensate pump

C.

Commissioning the humidifier

D.

Commissioning the cooling system

Buy Now
Questions 13

Which of the following conditions will not cause the wizard startup commissioning to fail?

Options:

A.

The condensate pump is stuck.

B.

The indoor fan 2 drive is faulty.

C.

The electronic expansion valve is not opened.

D.

The water leakage rope is not installed.

Buy Now
Questions 14

The rated output capability of a single power module for the UPS5000-H is how many kVA.

Options:

A.

50

B.

100

C.

30

D.

60

Buy Now
Questions 15

Which of the following is the cabling mode of external power cables in IT scenarios of the FusionDC1000A?

Options:

A.

Bottom cabling

B.

End wall cabling

C.

Top cabling

D.

End door cabling

Buy Now
Questions 16

The maintenance bypass switch cannot be turned on when the UPS5000-H works in normal mode.

Options:

A.

True

B.

False

Buy Now
Questions 17

What is the upstream input voltage range of the UPS5000-H?

Options:

A.

360 V–600 V

B.

220 V–240 V

C.

380 V–415 V

D.

138 V–485 V

Buy Now
Questions 18

The software installation package does not need to be downloaded for the preinstalled server.

Options:

A.

True

B.

False

Buy Now
Exam Code: H20-923_V1.0
Exam Name: HCSP-Field-Data Center Facility V1.0
Last Update: Feb 20, 2026
Questions: 60

PDF + Testing Engine

$49.5  $164.99

Testing Engine

$37.5  $124.99
buy now H20-923_V1.0 testing engine

PDF (Q&A)

$31.5  $104.99
buy now H20-923_V1.0 pdf
dumpsmate guaranteed to pass

24/7 Customer Support

DumpsMate's team of experts is always available to respond your queries on exam preparation. Get professional answers on any topic of the certification syllabus. Our experts will thoroughly satisfy you.

Site Secure

mcafee secure

TESTED 21 Feb 2026