Fire-Inspector-II 67 - Fire Inspector II Exam Questions and Answers

Questions 4

What fire-resistance rating is required for interior nonbearing walls and partitions in Type IV construction?

Options:

A.

0 hours

B.

1 hour

C.

1-1/2 hours

D.

2 hours

Buy Now
Questions 5

Horizontal exits shall not comprise more than ___ of the required exits from any floor area in a Group I-2 occupancy.

Options:

A.

1/3

B.

1/2

C.

2/3

D.

3/4

Buy Now
Questions 6

A bowling center with 25 lanes and 3,500 sq. ft. of additional area calculates to a maximum occupant load of how many people?

Options:

A.

125

B.

234

C.

500

D.

625

Buy Now
Questions 7

The minimum fire-flow for a 75,000-sq. ft. building of Type IIB construction without a sprinkler system is:

Options:

A.

3,000 gpm for 3 hours.

B.

4,000 gpm for 4 hours.

C.

5,500 gpm for 4 hours.

D.

5,750 gpm for 4 hours.

Buy Now
Questions 8

A "control area" is defined by the fire code as a building or portion of a building within which the exempted amounts of ___ are allowed to be stored, dispensed, used, or handled.

Options:

A.

hazardous materials

B.

flammable liquids only

C.

combustible liquids only

D.

corrosive materials only

Buy Now
Questions 9

What is the maximum travel distance to an exit from within a tent?

Options:

A.

75 ft.

B.

100 ft.

C.

150 ft.

D.

Any distance approved by the chief

Buy Now
Questions 10

The clearance requirement from structures for open burning may be reduced to a minimum of ___ ft. from a structure when the burning is conducted in an approved container.

Options:

A.

10

B.

15

C.

25

D.

50

Buy Now
Questions 11

Smoking is not permitted within ___ ft. of a transfer point for LP-gas while filling operations are in progress.

Options:

A.

10

B.

15

C.

25

D.

50

Buy Now
Questions 12

The minimum fire-flow for a 3,700-sq. ft. two-family dwelling of Type VB construction with a sprinkler system is ___ GPM.

Options:

A.

875

B.

1,000

C.

1,313

D.

1,750

Buy Now
Questions 13

Given: In organic coating processes where Class I liquids are exposed to the air, Class I, Division I electrical installations are required to be outside the immediate vicinity of pumps or equipment.

"Immediate vicinity" means in addition to a vertical distance a zone extending from the vapor liberation point __ ft. horizontally in all directions.

Options:

A.

5

B.

10

C.

20

D.

50

Buy Now
Questions 14

Atmospheric tanks with hazardous materials shall be equipped with a liquid-level limit control if they have a capacity which is greater than __ gallons.

Options:

A.

55

B.

100

C.

250

D.

500

Buy Now
Questions 15

A local board of appeals may perform all of the following functions except:

Options:

A.

waive requirements of the fire code.

B.

render interpretations of the fire code.

C.

approve alternate materials and types of construction.

D.

adopt rules and regulations for conducting its investigations.

Buy Now
Questions 16

The occupant load of an R-2 building's common patio area is to be calculated using the value:

Options:

A.

50 net per person.

B.

11 gross per person.

C.

15 gross per person.

D.

assigned by the code official.

Buy Now
Questions 17

Given: A nonsprinklered commercial Type II-B building has a fire flow requirement of 7,000 gpm. If a sprinkler system is installed throughout the building, the new required fire flow is at least ___ gpm. (Assume that the new required fire flow is sufficient to meet the requirements of the sprinkler system.)

Options:

A.

1,500

B.

1,750

C.

2,000

D.

2,250

Buy Now
Questions 18

Use, dispensing, and mixing of flammable liquids in open systems shall have continuous mechanical ventilation at a minimum rate of ___ CFM per sq. ft. of floor area.

Options:

A.

1

B.

2

C.

3

D.

4

Buy Now
Questions 19

The maximum combined quantity of Class II and III liquids which may be stored in a flammable liquids storage cabinet is __ gallons.

Options:

A.

10

B.

60

C.

120

D.

240

Buy Now
Questions 20

When investigating a complaint of a violation within an occupied public area, the fire inspector:

Options:

A.

must give prior notice to the occupant.

B.

need not give prior notice of the inspection to the occupant.

C.

must provide the occupant with at least 24 hours of advance notice.

D.

must either give prior notice to the occupant or obtain an inspection warrant.

Buy Now
Questions 21

When adequate openings are provided on only one exterior wall of a story in an office building, an automatic sprinkler system shall be installed when the wall opposite the openings is more than ___ ft. away.

Options:

A.

50

B.

75

C.

100

D.

150

Buy Now
Questions 22

Platforms used for access to aboveground tanks storing flammable or combustible liquids shall be:

Options:

A.

at least 4 ft. wide.

B.

built of noncombustible construction.

C.

built of nonferrous, nonsparking metal.

D.

located no closer than 3 ft. to the side of the tank.

Buy Now
Questions 23

The maximum time which a hazardous materials storage tank may be left unused, before safeguards as required by the code official are necessary, is ___ days.

Options:

A.

30

B.

60

C.

90

D.

120

Buy Now
Questions 24

A required standpipe shall be installed when the progress of construction above the lowest level of fire department access reaches a maximum of __ ft.

Options:

A.

30

B.

40

C.

55

D.

75

Buy Now
Questions 25

Quantities of flammable liquid storage in a control area of an S Occupancy may be doubled when:

Options:

A.

permission is granted by the chief.

B.

the control area exceeds 50,000 sq. ft.

C.

the building is protected with automatic sprinklers.

D.

the control area is provided with exhaust ventilation in accordance with fire code requirements.

Buy Now
Questions 26

Fine magnesium scrap stored in quantities greater than 1,000 cu. ft. shall be separated from all buildings other than those used for magnesium scrap recovery operations by a distance of not less than ___ ft.

Options:

A.

30

B.

50

C.

100

D.

250

Buy Now
Exam Code: Fire-Inspector-II
Exam Name: 67 - Fire Inspector II Exam
Last Update: Jun 10, 2025
Questions: 87

PDF + Testing Engine

$57.75  $164.99

Testing Engine

$43.75  $124.99
buy now Fire-Inspector-II testing engine

PDF (Q&A)

$36.75  $104.99
buy now Fire-Inspector-II pdf
dumpsmate guaranteed to pass
24/7 Customer Support

DumpsMate's team of experts is always available to respond your queries on exam preparation. Get professional answers on any topic of the certification syllabus. Our experts will thoroughly satisfy you.

Site Secure

mcafee secure

TESTED 12 Jun 2025